Measuring Amplifier X-201-IP07

particularly suitable for universal measurement amplification

For signal conditioning in static applications

The measuring Amplifier X-201-IP07 was developed for universal and simple operation. Zero adjustment is performed via the zero adjustment mechanism. Thanks to the robust aluminium housing, this measuring Amplifier is also suitable for direct mounting in harsh environmental conditions.

The X-201-IP07 Amplifier is particularly suitable for use in the following applications:

  • Weight measurement
  • Determination of mechanical loads in structures
  • Limit value monitoring and monitoring of mechanical loads to avoid critical conditions in plants and structures

Features:

  • Wide input range from 1.0 mV/V to 4.0 mV/V for universal connection of resistive strain, force and weight sensors
  • Teach-in of zero point with external reset or tare control input or via a push-button on the electronics, zero point correction is stored captive (installation tare)
  • With integrated measuring amplifier with optional ± 10 V or 4-20 mA / 0-20 mA as robust output signal, can be operated simultaneously

Installation and use

The measuring Amplifiers from X-Sensors are suitable for universal signal conditioning of resistive strain gauge measuring bridges and piezoresistive Sensors. They are thus suitable for amplifying the mV/V-Sensor signal from Force and Strain Sensors to control inputs. Thanks to the compact field housing, mounting can be carried out directly at the measuring point in a space-saving manner. This allows the strain gauge sensor signal to be amplified into a robust standard signal (0-10 V or 4-20 mA) on the spot.

Zero point taring

The zero point adjustment on these measuring Amplifiers is done by a digital zero point adjustment mechanism. The zero point setting is permanently stored, i.e. the zero point correction is available again even after switching off. Thus, a permanently available installation tare is available. Therefore, these measuring Amplifiers are suitable for all static applications. The number of taring operations is limited to 100,000.

Zero adjustment is triggered via an external reset or tare control input. The mechanism is available with “Active Low” and “Active High” logic.

Electrical connection

The measuring Amplifiers are available with voltage output (0-10 V) and current output (4-20 mA), which amplify strain gauge full bridges accordingly.

Technical data

measuring range

, , , , ,

design

Anwendung / Tarierung

,

Ausgangssignal

,

Electrical connection

(K) Input sensitivity (in mV/V)

1.0, 1.25, 1.5, 2.0, 3.0, 4.0

(K) Application

static

(K) Output signal

± 10 V, 0-10 V, 4-12-20 mA, 4-20 mA

(K) Electrical connection

M12 – 4-pin. socket, M12 – 8pol. plug

(K) Housing

Aluminum field housing

Contact us!

We are happy to answer your questions about our sensors and find a solution for your application.

    Name*

    Prename*

    Company

    Phone

    Zip*

    Mail*

    Your Message

    XSENSORS

    X-SENSORS AG

    If you have any questions about our products, we are at your disposal.

    info@x-sensors.com
    + 41 52 543 19 60
    Linkedin

    Compare